{"id":241,"date":"2016-11-25T12:29:43","date_gmt":"2016-11-25T03:29:43","guid":{"rendered":"http:\/\/192.168.99.100\/?page_id=241"},"modified":"2018-02-23T17:58:55","modified_gmt":"2018-02-23T08:58:55","slug":"pulse-type-solar-simulator-for-solar-module-evaluation","status":"publish","type":"page","link":"https:\/\/yamashitadenso.co.jp\/english2\/product\/product01\/pulse-type-solar-simulator-for-solar-module-evaluation","title":{"rendered":"Pulse type solar simulator for solar module evaluation"},"content":{"rendered":"<!--block_01 \u25bc-->\r\n\r\n<section id=\"block_01\">\r\n<h3>Pulse type solar simulator for solar module evaluation<\/h3>\r\n<!--intro \u25bc-->\r\n<div id=\"intro\">\r\n<p class=\"pic\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-242\" src=\"https:\/\/yamashitadenso.co.jp\/english2\/wp-content\/uploads\/2016\/11\/product01-item08.jpg\" alt=\"product01-item08\" width=\"360\" height=\"290\" srcset=\"https:\/\/yamashitadenso.co.jp\/english2\/wp-content\/uploads\/2016\/11\/product01-item08.jpg 360w, https:\/\/yamashitadenso.co.jp\/english2\/wp-content\/uploads\/2016\/11\/product01-item08-300x242.jpg 300w\" sizes=\"auto, (max-width: 360px) 100vw, 360px\" \/><\/p>\r\n\r\n<div>\r\n\r\nAs a module tester of solar cell module production line.\r\nModule evaluation device optimized for production line with energy saving, long running life, low running cost, good maintainability.\r\nJointly developed product with National Institute of Advanced Industrial Science and Technology.\r\n\r\n<\/div>\r\n<\/div>\r\n<!--intro \u25b2-->\r\n\r\n<!--feature \u25bc-->\r\n\r\n<section id=\"feature\">\r\n<h4><img decoding=\"async\" src=\"\/english2\/wp-content\/themes\/yamashita\/images\/h_product_item_feature.png\" alt=\"Product features\" \/><\/h4>\r\n<ul class=\"point\">\r\n \t<li><img decoding=\"async\" src=\"\/english2\/wp-content\/themes\/yamashita\/images\/icon_company01_01_1.png\" alt=\"1\" \/>Considering the electrical and optical responsiveness of the solar module,<span class=\"number_space\"><\/span>we extended the light emission pulse width<\/li>\r\n<\/ul>\r\n<ul style=\"padding-left: 70px; padding-bottom: 20px; margin-top: 0px;\">\r\n \t<li>Pulse width: 100msec<\/li>\r\n \t<li>Light waveform: Quasi-trapezoidal waveform<\/li>\r\n<\/ul>\r\n<ul class=\"point\">\r\n \t<li><img decoding=\"async\" src=\"\/english2\/wp-content\/themes\/yamashita\/images\/icon_company01_01_2.png\" alt=\"2\" \/>Repeatable light emission interval (within several seconds)<\/li>\r\n<\/ul>\r\n<ul style=\"padding-left: 70px; padding-bottom: 20px;\">\r\n \t<li>Charging time: Min. 15sec<\/li>\r\n<\/ul>\r\n<ul class=\"point\">\r\n \t<li><img decoding=\"async\" src=\"\/english2\/wp-content\/themes\/yamashita\/images\/icon_company01_01_3.png\" alt=\"3\" \/>Achieve both high speed sweep speed and high accuracy<\/li>\r\n<\/ul>\r\n<ul style=\"padding-left: 70px; padding-bottom: 20px;\">\r\n \t<li>I \/ V measurement \u00b7 Normal mode<\/li>\r\n \t<li>Up to 1,000 points can be measured (1 pulse: 100msec)<\/li>\r\n \t<li>The number of measurement points can be set arbitrarily.<\/li>\r\n \t<li>Precision mode (1 point measured with 1 pulse)<\/li>\r\n<\/ul>\r\n<ul class=\"point\">\r\n \t<li><img decoding=\"async\" src=\"\/english2\/wp-content\/themes\/yamashita\/images\/icon_company01_01_4.png\" alt=\"4\" \/>Light source unit that can be optimized for characteristics of target measurement item<\/li>\r\n<\/ul>\r\n<ul style=\"padding-left: 70px; padding-bottom: 20px;\">\r\n \t<li>The spectral distribution of the irradiation light can be optimized according to the spectral sensitivity characteristics of the solar module.<\/li>\r\n<\/ul>\r\n<ul class=\"point\">\r\n \t<li><img decoding=\"async\" src=\"\/english2\/wp-content\/themes\/yamashita\/images\/icon_company01_01_5.png\" alt=\"5\" \/>It is the light source part most suitable for the production line,<span class=\"number_space\"><\/span>and it also supports large area modules<\/li>\r\n<\/ul>\r\n<ul style=\"padding-left: 70px; padding-bottom: 20px;\">\r\n \t<li>Effective irradiation area: 1m x 1.9m, 1.2m x 1.9m, 1.4m x 1.9m (Standard type)<\/li>\r\n \t<li>We can produce 2m to 10m in longtitudinal.<\/li>\r\n<\/ul>\r\n<ul class=\"point\">\r\n \t<li><img decoding=\"async\" src=\"\/english2\/wp-content\/themes\/yamashita\/images\/icon_company01_01_6.png\" alt=\"6\" \/>It has an appearance and structure easy to incorporate into the<span class=\"number_space\"><\/span>production line (power supply section is separate)<\/li>\r\n<\/ul>\r\n<ul style=\"padding-left: 70px; padding-bottom: 20px;\">\r\n \t<li>2,600 (L) x 1,500 (W) x 1,000 (H), 1200 kg (standard type \u00b7 light source part)<\/li>\r\n<\/ul>\r\n<ul class=\"point\">\r\n \t<li><img decoding=\"async\" src=\"\/english2\/wp-content\/themes\/yamashita\/images\/icon_company01_01_7.png\" alt=\"7\" \/>Device performance<\/li>\r\n<\/ul>\r\n<ul style=\"padding-left: 70px; padding-bottom: 20px;\">\r\n \t<li>In accordance with JIS C 8912, C 8933, IEC \/ EN.60904 &#8211; 9, ASTM &#8211; E 927 standard, class AAA (Class AAA)<\/li>\r\n \t<li>Spectral match : A<\/li>\r\n \t<li>Light temporal instability :A<\/li>\r\n \t<li>Non-uniformity of irradiance: A<\/li>\r\n \t<li>JIS C 8912: Solar simulator for measuring crystalline solar cells<\/li>\r\n \t<li>JIS C 8933: Solar simulator for amorphous solar cell measurement<\/li>\r\n<\/ul>\r\n<ul class=\"point\">\r\n \t<li><img decoding=\"async\" src=\"\/english2\/wp-content\/themes\/yamashita\/images\/icon_company01_01_8.png\" alt=\"8\" \/>Long life lamp<\/li>\r\n<\/ul>\r\n<ul style=\"padding-left: 70px; padding-bottom: 20px;\">\r\n \t<li>over 1,000,000 pulses<\/li>\r\n \t<li>Lamp replacement is excellent in maintainability and has high light reproducibility. Low running cost.<\/li>\r\n<\/ul>\r\n<ul class=\"link\">\r\n \t<li><a href=\"https:\/\/yamashitadenso.co.jp\/english2\/contact\">Product inquiries<\/a><\/li>\r\n<\/ul>\r\n<\/section><!--feature \u25b2-->\r\n\r\n<\/section><!--block_01 \u25b2-->","protected":false},"excerpt":{"rendered":"Pulse type solar simulator for solar module evaluation As a module tester of solar cell module production line [&hellip;]","protected":false},"author":4,"featured_media":0,"parent":162,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page_item.php","meta":{"footnotes":""},"class_list":["post-241","page","type-page","status-publish","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/yamashitadenso.co.jp\/english2\/wp-json\/wp\/v2\/pages\/241","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yamashitadenso.co.jp\/english2\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/yamashitadenso.co.jp\/english2\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/yamashitadenso.co.jp\/english2\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/yamashitadenso.co.jp\/english2\/wp-json\/wp\/v2\/comments?post=241"}],"version-history":[{"count":22,"href":"https:\/\/yamashitadenso.co.jp\/english2\/wp-json\/wp\/v2\/pages\/241\/revisions"}],"predecessor-version":[{"id":982,"href":"https:\/\/yamashitadenso.co.jp\/english2\/wp-json\/wp\/v2\/pages\/241\/revisions\/982"}],"up":[{"embeddable":true,"href":"https:\/\/yamashitadenso.co.jp\/english2\/wp-json\/wp\/v2\/pages\/162"}],"wp:attachment":[{"href":"https:\/\/yamashitadenso.co.jp\/english2\/wp-json\/wp\/v2\/media?parent=241"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}